Skip to content
Call (863) 312-5129 Get Free Estimate

Pellet Stove Installation for Lakeland Homes

A pellet stove or pellet insert set to its manual: floor protection, clearances, listed vent and a start-up test.

  • Licensed & insured
  • Owned and run locally
  • Family owned and run
  • Same-day service available

Get Your Free Inspection

Prefer the phone? Call (863) 312-5129

Signs It Is Time to Call

Pellet stoves are easy to buy and easy to install wrongly, because the vent, the floor and the electric supply all matter. Our family-owned Lakeland crew installs freestanding pellet stoves and pellet inserts to the maker's manual. The free inspection looks at the room, the wall and the vent route, and the written estimate covers the whole job.

  1. A pellet stove or insert bought and waiting to be installed
  2. An old fireplace you want to fit with a pellet insert
  3. A room with no chimney where you want a pellet stove vented through a wall
  4. A stove that was installed before and now needs its vent or floor corrected

What Your Free Inspection Covers

  1. Choosing the spot against the manual's clearances to walls and furniture
  2. Floor protection under and in front of the stove
  3. The listed pellet vent run through a wall or up an existing chimney
  4. Outside-air connection where the maker requires it
  5. A start-up test and a walk-through of the controls
Jump to

The Work, Explained

Freestanding stove or pellet insert

A freestanding stove sits on the floor in the room and vents out the back, usually through the wall. A pellet insert slides into an existing fireplace and vents up the chimney through a pipe run the length of the flue. The choice usually follows what you already have: a room without a fireplace calls for the stove, and a fireplace you no longer burn calls for the insert.

If you are weighing a pellet insert against a wood or gas insert, see fireplace insert installation. Pellet stove insert installation sends the vent pipe up the existing chimney, and pellet stove vent installation for a freestanding stove takes it through the wall. Either way it is pellet stove pipe installation with the listed vent the manual names, and pellet stove chimney installation means the same pipe run inside a chimney. Pellet stove installers should start from the manual, and so do we.

The manual sets the clearances and the floor

Every pellet stove is tested and listed, and its manual gives the distance it must keep from side walls, back wall and corners, and the size of the floor protection under it and in front of the ash door. Those figures differ from one stove to another, so we do not work from a rule of thumb. We read the manual for your model and mark the floor and wall before anything is moved.

If you have not yet bought the stove, tell us the room and we will help you choose a position that works. If the stove is already in the garage, read us the model number from the back.

The pellet vent is its own system

A pellet stove does not use an ordinary chimney connector. It uses a listed pellet vent, a sealed pipe that the maker specifies, run out through a wall with the right thimble or up an existing chimney. We use the pipe the manual names, not substitute stovepipe or dryer duct, and we seal every joint it says to seal.

A vent that is too long, has too many turns or ends too low will make the stove struggle. We plan the run on paper first and take the final termination point to you before we cut anything. On an insert, the existing chimney is checked first, because a blocked or damaged flue should not be used. See chimney inspection.

Outside air, power and safety devices

For fireplaces, the Florida Building Code requires an exterior air supply unless the room is mechanically ventilated (R1006). A pellet stove follows its own manual instead, and we connect outside air wherever that manual requires it.

A pellet stove has an auger, fans and controls, so it needs a power outlet near the stove, and the manual says what the stove does when power fails. Make sure a smoke alarm and a carbon monoxide alarm are working in the house. A stove that smells of exhaust, or that sets off a carbon monoxide alarm, should be shut off and the house aired out.

Start-up, the first fire and the handover

Once the stove is set and vented, we fill the hopper with pellets, run the start-up, watch the flame and the exhaust, and check that every connection holds. We then go through the controls and the cleaning schedule that the manual sets. A stove that works on day one needs regular cleaning, and we offer that as a separate pellet stove service visit.

The free inspection and the written estimate

We visit you in Lakeland, Winter Haven or Auburndale, look at the room, the wall and the vent route, and read the stove's manual. The free written estimate names the stove position, the floor protection, the vent parts and the work.

The crew is local, family owned, experienced and Proudly American. Call (863) 312-5129 or send the inspection request.

What a Visit From Our Lakeland Team Looks Like

Pellet stove installation places a freestanding stove or an insert on protected floor, connects it to a listed pellet vent through a wall or up an existing chimney, and wires it to power. Clearances, floor protection and the outside-air connection come from the manual of that exact stove, and a start-up test closes the job.

  • Family owned and run

    A family-owned company installs your stove and answers for the vent.

  • Experienced crew

    An experienced crew follows the manual for your exact model.

A Service Offer After Your Inspection

After the free inspection, you have 72 hours to book any service with 10% off.

Get Free Estimate

Questions Lakeland Homeowners Ask Us

Can a pellet stove be installed without a chimney?

Yes. A freestanding pellet stove can vent through an exterior wall with a listed pellet vent. The manual for the stove gives the pipe type, the height of the termination and its distance from windows and doors. We install to those numbers.

Does a pellet stove need electricity?

Yes. The auger, the fans and the controls run on household power, so the stove needs an outlet within reach. The manual explains what the stove does when power is lost and how it restarts.

What floor protection does a pellet stove need?

The size and the material come from the stove's listing and manual, and they vary by model. We lay out the protection to those dimensions before the stove is moved into place.

Chimney & Fireplace Brands We Work With

DuraVentOlympia Chimney and VentingCopperfield Chimney SupplyRutlandHeatilatorHeat & Glo

Call a Chimney Company That Stays Local

Calling from Lakeland, Winter Haven or Auburndale? Tell us what the fireplace or chimney is doing, and we will set up a free inspection, quote the job in writing and start only after you say yes.