Gas Fire Pit and Fire Table Repair for Lakeland Patios
A fire pit that clicks but never lights, or lights and then dies, has a cause we can find and fix.
- Licensed & insured
- Owned and run locally
- Family owned and run
- Same-day service available
Get Your Free Inspection
Thank you for the details
We will follow up to agree on an appointment.
Prefer the phone? Call (863) 312-5129
Signs It Is Time to Call
When a gas fire pit or fire table clicks and never lights, or lights and then goes out, the cause is usually small and findable. Our local, family-owned crew works on patio pits and fire tables across Lakeland, Winter Haven and Auburndale. Tell us the make and what the burner does; the free inspection ends with a written estimate.
- The igniter clicks but the burner never catches
- The flame starts, then drops out when you let go of the knob
- Flames only along one side of the burner
- A weak, low or yellow flame
- Glass, lava rock or other media that has shifted or cracked
- A faint gas smell near the pit after it has been off
What Your Free Inspection Covers
- Which part is failing: igniter, sensor, valve, regulator or burner
- Cleaning of burner ports and resetting the media to the maker's layout
- Replacement parts matched to your make and model
- Leak check of the appliance-side connections and a written record of the work
Jump to
The Work, Explained
What is wrong when a gas fire pit will not light
Nearly every outdoor gas fire pit and fire table does the same four things in order. Gas reaches a valve, the valve feeds a burner, a spark or pilot lights the gas, and a sensor decides whether the flame is real. When a pit will not light or will not stay lit, one of those four steps is failing. The job is to find which one before any part is replaced.
The common culprits on patio pits are a worn spark igniter, a flame sensor or thermocouple that has gone weak, a valve that no longer opens fully, burner ports plugged by debris or insects, and media piled too thickly over the burner. A tank-fed pit adds the regulator and the tank valve to that list. Fire pit igniter replacement is one outcome of that search, and a gas fire pit service visit covers the same four steps. Gas fire pit maintenance, the upkeep between visits, is covered near the end of this page. Gas fire table repair and outdoor fire pit repair follow the same four steps, because a fire table is a fire pit built into a table.
Signs the igniter, thermocouple or valve is the problem
A clicking sound with no flame points at the ignition side. The spark may be weak, the electrode may have shifted or corroded, or the gap between electrode and burner may have changed.
A flame that lights while you hold the knob and dies when you release it is a different story. That is the safety sensor telling the valve there is no proof of flame, and the sensor, its wiring or the valve is the usual cause. A pit that lights fine but only burns low points at the valve, the supply pressure or the burner itself.
- Clicks, no flame: igniter, electrode or its wiring
- Lights, then dies when released: thermocouple, flame sensor or valve
- Lights but stays weak: valve, regulator or blocked burner ports
- Uneven flame: blocked ports or media sitting where it should not
Why burner ports clog and what that does to the flame
A fire pit sits idle for weeks at a time, and the burner is an inviting dark tube. Spiders, wasps and ants nest in the burner and the air mixer, and leaves, pollen and dust settle into the ports. Gas then burns only where it can still get out, so the flame goes lopsided, lazy or yellow, or fails to carry across to the sensor.
Media causes its own trouble. Lava rock, fire glass or ceramic stones are meant to rest over the burner in the maker's pattern. Piled too deep, or with fine broken pieces filtering down into the ports, they smother the flame and can keep the sensor cold. Cleaning the burner and putting the media back to the maker's layout fixes a surprising number of fire pits.
What you can safely check before you call
Start with the plain things. Make sure the control knob or remote has fresh batteries, the shutoff valve is open, and on a propane pit the tank is not empty. Check that no water has pooled in the burner pan after rain, and lift off any cover or lid the maker's manual says must stay clear. Your pit's manual says how its tank valve and regulator should be handled.
Stop there. Do not take the burner apart, bend an electrode, jumper the sensor or tighten gas fittings. Do not keep trying to light a pit that has not caught after a couple of attempts; let the gas clear for the time your manual states first. If you smell gas, turn the supply off at the shutoff if you can do so safely, move everyone away and call the gas utility or 911 from a safe distance.
Keep the fire pit outdoors, in open air
A gas fire pit is an outdoor appliance, and it should stay outdoors in open air. Carbon monoxide is colorless and odorless, and the US Fire Administration notes it can build up when a fuel-burning appliance is not working or vented properly. Keep working CO alarms on every level of the home, and follow your pit's manual on where it may be used.
The Florida Building Code, Residential, chapter 24, requires permanently fixed outdoor decorative appliances to be listed to ANSI Z21.97 and installed according to the manufacturer's instructions. That is also why repairs use the parts made for the unit instead of a burner or valve borrowed from something else.
What the repair visit includes
We start by identifying the fire pit or table, the fuel it runs on and how it is controlled. Then we watch it try to light, check the ignition spark, test the sensor and valve, and inspect the burner ports and the media. Gas connections on the appliance side are checked for leaks before we leave.
You get the finding in plain words and a written estimate before any part is ordered. Parts we commonly replace on outdoor units are igniters and electrodes, thermocouples and sensors, control valves, remote receivers and burners. When the cause is only debris or media, the fix is a cleaning and a reset. A written record of the work comes with the job.
What changes the scope of the job
Fire pit repair stays on the appliance. We do not build fire pits, run a new gas line or refill or sell propane tanks. If a pit needs a gas supply that is not there, that is a separate trade, and we will say so in the estimate.
Three things decide how big a repair becomes: the age and make of the pit, whether replacement parts are still sold for it, and how much weather damage has reached the burner and wiring. A newer pit with a failed igniter is a short job. An older pit with a rusted burner and a failed valve may be better replaced than repaired, and we will tell you which side of that line yours is on.
Keeping a fire pit lighting season after season
Cover the pit when it is not in use, using the cover the maker supplies or one made for the shape. Keep the burner pan drained and clear of leaves. Before the first cool evening, light the pit once and look at the flame. Even blue flame along the whole burner means the ports are clear; gaps, yellow tips or a weak flame are early notice to call.
If you are also weighing an indoor gas appliance, our gas fireplace repair page covers log sets, inserts and fireplaces. For an outdoor fire pit that will not behave, call us or send a request, and we will set a time for a free inspection and a written estimate. We are local, family owned, an experienced crew, and Proudly American.
Related Chimney Services
What a Visit From Our Lakeland Team Looks Like
Gas fire pit repair finds and fixes the part that stops an outdoor pit or fire table from lighting or staying lit. The usual causes are a worn igniter, a weak thermocouple or sensor, a tired valve, burner ports clogged by debris or insects, and media piled over the burner.
-
Family owned and run
A local family-owned company answers for the repair on your patio.
-
Experienced crew
An experienced crew traces the failing part instead of swapping parts to see what sticks.
A Service Offer After Your Inspection
After the free inspection, you have 72 hours to book any service with 10% off.
Questions Lakeland Homeowners Ask Us
Why won't my gas fire pit stay lit?
A pit that lights and then goes out when you release the knob usually has a weak thermocouple or flame sensor, a loose connection, or media sitting on the sensor. Debris in the burner ports can also keep the flame from reaching it. The sensor and valve are tested together before either is replaced.
My fire pit clicks but won't light. What is wrong?
Clicking with no flame points at the ignition side or the gas supply. The electrode may be corroded or out of position, the igniter wiring may be loose or wet, or the valve may not be opening. On a propane pit, check the tank first, since an empty tank looks the same as a failed part.
Can insects really stop a gas fire pit from working?
Yes. Spiders, ants and wasps build nests in the burner and the air mixer, and the nest blocks the flow of gas or air. The flame then burns lopsided, lazy or yellow, or never lights. Cleaning the burner and mixer usually brings it back, and a cover keeps them out afterward.
Is a gas fire table repaired the same way as a fire pit?
The parts are nearly the same: igniter, sensor, valve, burner and media. A fire table adds a tight enclosure and often a concealed control panel, so the access is different and some work means lifting the top. The repair still starts with finding which part fails and ends with a leak check.
Chimney & Fireplace Brands We Work With


Call a Chimney Company That Stays Local
Calling from Lakeland, Winter Haven or Auburndale? Tell us what the fireplace or chimney is doing, and we will set up a free inspection, quote the job in writing and start only after you say yes.