A laundry with no duct to the outside
A new run from the dryer to the nearest allowed wall
Length counted against the maker's instructions

A new or moved dryer duct in smooth metal on the shortest, straightest path, ending in a hood that opens with the air.
Get Your Free Inspection
Thank you for the details
We will follow up to agree on an appointment.
Prefer the phone? Call (863) 312-5129
Some dryer vents are poorly planned from the start. A new laundry spot, a replaced dryer or a run that takes many turns through an attic all call for the same fix, a duct planned from scratch. Our family-owned Lakeland crew installs and reroutes dryer vents in smooth metal, ending in a proper hood. The free inspection comes with a written estimate.
Dryer vent installation means building the exhaust path from the dryer to the outdoors. It covers a laundry room that never had a vent, a dryer that has been moved, and a vent that was built badly the first time. Rerouting is the same work on a house that already has a vent. The duct is moved from where it exits now to a shorter, straighter route.
Fixing a damaged run that is in the right place is dryer vent repair. Clearing lint from a run that is sound is dryer vent cleaning. This page is about the route itself. Dryer duct installation, a dryer vent reroute and a dryer vent rerouting service are the same family of work. If you want to move a dryer vent, or to move the vent from the roof to a wall, the job is a roof to wall dryer vent conversion, and the new run follows the rules below. Dryer vent booster fan installation is not our answer to a long run, because section M1502.4.8 prohibits domestic booster fans in dryer exhaust systems.
The best vent is the short one. Whirlpool's dryer instructions say to use the straightest path possible when routing the vent, and every bend and every foot slows the air and gives lint a place to settle. We walk the house, find the closest exterior wall that the dryer maker's instructions and the code allow, and plan the run from there.
That plan weighs what is in the walls and the ceiling, how far the dryer must sit from the wall and where a hood can go outside without sitting too close to a window, a door or a soffit vent. You see the route on the written estimate before any wall is opened.
The 2023 Florida Building Code, Residential, section M1502.4.5.1, sets a maximum exhaust duct length of 35 feet, measured from the connection to the transition duct to the outlet. Fittings cut that figure. The table in the code counts each elbow as a number of feet, and three of its entries are shown below.
Section M1502.4.5.2 hands the final say to the dryer maker. The size and the longest length come from the maker's installation instructions for the exact dryer, and the code official is to be given a copy of them at the concealment inspection. A run with an equivalent length over 35 feet also has to carry a label with that length, within 6 feet of the connection, under section M1502.4.6.
Under section M1502.4.1 the duct is metal with a smooth interior, at least 28 gauge, 4 inches nominal. Section M1502.4.2 asks for supports no more than 12 feet apart, joints sealed and no screws or similar fasteners holding ducts together. Whirlpool says the same in plainer words, use clamps and do not let tape or screws reach into the vent.
At the dryer, the transition duct is a single length, listed and labeled to UL 2158A, no more than 8 feet long and never hidden inside construction under M1502.4.3. The Consumer Product Safety Commission advises metal in place of plastic or foil, since plastic and foil kink and crush more easily and trap more lint. Where a duct passes within 1 1/4 inches of the face of the framing, section M1502.5 asks for steel shield plates so a nail or screw cannot reach it.
The run ends at a hood outside, with a backdraft damper and no screen, as section M1502.3 requires. Where the maker names no location, the hood sits at least 3 feet from openings into the building, soffit vents included.
A roof termination is exposed to sun and rain and is hard to reach, and the run behind it climbs. Moving the exit to a side wall can shorten the duct and put the hood where it can be checked from the ground. The roof opening is closed and sealed, the new duct is run in smooth metal and a new hood goes on the wall.
Not every house allows it. A laundry in the middle of a house, a second floor or a tight attic can leave the roof as the better route. We look at both and tell you which is shorter and straighter.
A fan is a last step, not a first answer. Section M1502.4.4 requires a power ventilator in a dryer exhaust to be listed to UL 705 and installed to its maker's instructions, and section M1502.4.8 prohibits domestic booster fans in dryer exhaust systems, so a shorter route comes first. If a run truly cannot be shortened, we discuss the options with you and the maker's instructions decide. House wiring for any fan is work for an electrician.
We install the exhaust duct and its hood. We do not connect or move a gas line, and we do not wire a dryer outlet, because those are jobs for a gas fitter and an electrician. We also do not repair the dryer itself. If the dryer you are moving needs any of that, we plan the vent around it and tell you who to call.
The distance to a wall that can take a hood, the number of turns, what the duct has to pass through and whether it runs through an attic, a wall cavity or a ceiling all change the work. A second-floor laundry with a long vertical run is a bigger job than a ground-floor laundry beside an outside wall. Your free inspection sorts out which one you have.
The house decides whether the job is a new run, a move or a shorter route.
A new run from the dryer to the nearest allowed wall
Length counted against the maker's instructions
Move the exit to a side wall and seal the roof opening
A shorter duct and a hood within reach
Discuss options, with the maker's instructions deciding
A listed fan only if the maker's instructions allow it
Dryer vent installation runs a new smooth metal duct from the dryer to the outside on the shortest, straightest path the house allows. Rerouting moves an existing vent, for example from the roof to a side wall. Both end in a hood with a backdraft damper and follow the dryer maker's instructions and the Florida Building Code.
The route, the materials and the price are written down before a wall is opened.
You keep a written record of the new route and what we fitted.
A Lakeland crew that plans the run for your house, not a template.
Book the new run within 72 hours of your free inspection and the job is 10% off.
A proper dryer vent runs the shortest, straightest path from the dryer to the outside in smooth 4 inch metal duct. Joints are sealed and supported, one short listed transition hose joins the machine, and the run ends in a hood with a backdraft damper and no screen. The dryer maker's instructions set the longest allowed length.
Under section M1502.4.5.1 of the 2023 Florida Building Code, a dryer duct can run up to 35 feet, less an allowance for each elbow. The 35 feet runs from the transition hose to the outlet, and a 4 inch mitered 90 degree elbow counts as 5 feet. The dryer maker's instructions can set a different limit, and we follow the maker's.
A dryer vent should end on the outside of the building, never in an attic, a soffit or a crawl space. Where the dryer maker names no location, the code puts the hood at least 3 feet from any opening into the building, soffit vents included. We also choose the spot that gives the duct the fewest bends.
Yes, a roof run can often be rerouted to a side wall, which usually shortens the duct and removes the roof opening. The old opening is closed and sealed, and the new run follows the same rules as any other, including a hood with a damper. The route depends on where the laundry sits in the house.


A local, family-owned and experienced crew runs the duct and tests the air. Proudly American.
The inspection costs nothing. Schedule any service in the 72 hours after it to get a 10% discount.
Thank you for the details
We will follow up to agree on an appointment.
Prefer the phone? Call (863) 312-5129