How to Turn a Gas Fireplace Into a Wood-Burning One
Going back to wood depends on the kind of gas fireplace you own, and often means a different appliance and not just a change of fuel.
- Licensed & insured
- Owned and run locally
- Family owned and run
- Same-day service available
Get Your Free Inspection
Thank you for the details
We will follow up to agree on an appointment.
Prefer the phone? Call (863) 312-5129
Short version
Turning a gas fireplace into a wood-burning one works only if the firebox was built for wood. A gas log set in a masonry fireplace can come out, the gas line can be capped and the flue checked. A factory-built gas fireplace is listed for gas, so a wood fire there means installing a wood-listed unit instead.
Jump to
The Work, Explained
Which kind of gas fireplace do you have?
- Ceramic logs
- Burner
- Pilot
- Gas valve
- Gas supply line
- Firebox
Searches for a gas fireplace mix up two different things. One is a set of gas logs sitting in a fireplace that was built for wood. The other is a gas fireplace appliance, a factory-built box with its own burner, glass front and vent pipe. The road back to wood is different for each, so identify yours first.
The rating label inside the firebox or behind the control panel gives the model name and says what the unit is listed for, and the owner's manual repeats it. These signs help when the label is gone.
- Gas logs in a masonry fireplace: a brick or stone firebox, a damper above the opening, a burner pan with ceramic logs and a gas pipe coming up through the hearth
- Factory-built gas fireplace: a metal firebox with a glass front, usually framed into a wall or chase, with a rating label and a vent pipe that runs up or out through the wall
- Gas insert: a metal unit slid into an existing fireplace opening, which a maker describes as usually installed in an existing chimney with an approved flue liner
Gas logs in a masonry fireplace: the easier road back
A fireplace built for wood stays a wood fireplace underneath the logs. Going back usually means removing the log set and burner, shutting off and capping the gas pipe, and making sure the firebox and flue are ready for a wood fire. A maker's vent-free log set manual says solid fuels should not be burned in a fireplace in which its log set is installed, so the logs and burner come out before the first wood fire.
Check the damper too. Section R1001.7.1 of the 2023 Florida Building Code, Residential, says a masonry fireplace has a metal damper that can be operated from the room. A log set run with the damper clamped open needs the clamp removed and the damper tested, because wood smoke has to be able to leave through a flue that opens and closes freely.
Factory-built gas fireplaces are not wood fireplaces
A factory-built fireplace is listed and tested as one complete system. Section R1004.1 of the Florida code requires factory-built fireplaces to be listed and labeled, installed to the conditions of the listing and tested to UL 127. One maker's direct vent fireplace manual says that under no circumstances should any solid fuels, wood or paper, be used in the appliance.
The glass front, the controls and the vent system were all tested for gas. Burning wood in the box uses it outside its listing, and no adjustment fixes that. The vent is a separate issue, because section R1005.3 requires a factory-built chimney serving a solid-fuel appliance to meet UL 103 and carry the marking the section names. A vent pipe without that marking is not one to reuse for wood.
If a wood fire in that spot is what you want, the honest answer is a replacement. That means a wood-burning fireplace or insert listed for the job, with the chimney or chase and the clearances its listing calls for.
The flue and the damper come first
Having burned gas for a long time does not mean the flue is ready for wood. A vent-free log set manual says that before a log set goes into a solid-fuel fireplace the flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner, and that a damaged flue is repaired before use. The same care applies when you go back the other way.
Section R1003.11 of the Florida code says a masonry chimney is lined, with a lining appropriate for the type of appliance connected and the terms of its listing. Section R1003.11.1 then lists the linings it accepts for residential-type appliances, among them clay flue lining, a listed lining system and a factory-built chimney listed for installation within a masonry chimney. Section R1006.1 also calls for an exterior air supply to a fireplace unless the room is mechanically ventilated and kept at neutral or positive pressure.
A flue that has sat unused for a season can hold debris or damage that nobody has looked at, which is one more reason the inspection comes before the first fire and not after.
What happens to the gas line
Turning the control to off does not remove the gas line. Section G2420.5 of the code gives each gas appliance its own shutoff valve, and when an appliance comes out the pipe that fed it has to be closed off properly, not left with a loose connector hanging or a valve as the only barrier.
Section G2417.1.2 says that where piping is repaired or added to after the pressure test, the affected piping is tested again. Capping a line and testing it is gas fitting work, and it is not a Saturday project. If you ever smell gas, leave the house and call the gas supplier from outside.
Permits and your building department
Florida Statute 553.79 makes it unlawful to construct, erect, alter, modify, repair or demolish a building without first getting a permit from the enforcing agency, and the statute lists its own exceptions. Whether pulling out a log set or swapping an appliance needs a permit is for the building department of your city or county to say, so ask before the work starts and keep any permit paperwork with the house records.
Going the other way: turning a wood fireplace into a gas one
Many of these searches run in the opposite direction. A masonry wood fireplace can take a gas log set, and section G2432.1 of the Florida code says decorative appliances for approved solid-fuel fireplaces are listed to ANSI Z21.60 and installed to the maker's instructions. Section G2432.2 adds a flame safeguard that shuts off the fuel when the means of ignition fails.
The other route is a gas insert, which a maker says usually goes in an existing chimney with an approved flue liner. A vent-free log heater does not belong in a factory-built fireplace unless that fireplace was tested and listed for it (R1004.4), and some local codes allow only vented gas logs, so check before buying. The choice between vented and vent-free logs is a separate decision with its own page.
If your question was how to turn a gas fireplace on
The lighting instructions printed on your own unit are the authority, because pilot, remote and electronic systems each start differently. One maker's instructions for a manually lit pilot have you smell around the unit and near the floor for gas first, turn the control knob to OFF and wait five minutes before lighting the pilot. If the unit clicks and will not light, or you smell gas at any point, stop, shut off the gas supply and call the gas supplier from outside.
Next step
Whether the answer is a log set coming out, a flue check or a new unit, it starts with someone looking at what you have. Lakeland Chimney Service is a local, family-owned company, and our experienced crew is Proudly American. The gas fireplace installation page explains how that work goes. Call for a free inspection and a free written estimate.
Sources
- 2023 Florida Building Code, Residential, chapter 10 Chimneys and Fireplaces: R1001.7.1 damper, R1003.11 flue lining, R1004.1 and R1004.4 factory-built fireplaces, R1005.3 UL 103 chimney marking for solid-fuel appliances, R1006.1 exterior air
- 2023 Florida Building Code, Residential, chapter 24 Fuel Gas: G2420.5 appliance shutoff valve, G2417.1.2 retest after repairs, G2432.1 and G2432.2 decorative appliances for solid-fuel fireplaces
- Florida Statutes 553.79, permits and applications for the building code: Permit required before construction, alteration, modification or repair of a building, with the statute's own exceptions
- Vent-free yellow flame gas log heater owner's manual, models FLM18-1-LP and FLM18-1-NG, document 200365-01B (maker manual): Solid fuels not burned where a log set is installed; flue and firebox cleaned before use; damper clamp; lighting steps for a manual-pilot unit
- Kingsman ZCV39 and ZCV42 direct vent gas fireplace installation and owner's manual (maker manual): No solid fuels (wood, paper) in a direct vent gas fireplace
- Kingsman, fireplace basics: product options (maker page): Inserts installed in an existing chimney with an approved flue liner
Urgent Chimney Concern?
Arrange service after immediate hazards have been addressed.
For fire, suspected gas or a carbon monoxide alarm, leave and call 911 from outside.
What a Visit From Our Lakeland Team Looks Like
-
Family owned and run
Call a family-owned business that explains the job before any work begins.
-
Owned and run locally
Locally owned and operated from our Lakeland office, with work limited to Lakeland, Winter Haven and Auburndale.
-
No hidden fees
The agreed task and price are discussed together. Added work requires another conversation.
-
Workmanship warranty
Repair workmanship is backed by a warranty. Ask what the completed job covers and how to care for it.
Questions Lakeland Homeowners Ask Us
What is a wood burning gas fireplace?
No single appliance is both. The phrase usually describes a masonry wood fireplace fitted with a gas log set, which burns gas while the firebox stays a wood firebox. A maker's vent-free log set manual says solid fuels should not be burned in a fireplace where its log set is installed, so the setup runs one fuel at a time.
How to turn a gas fireplace into an electric one?
An electric fireplace is a different appliance, so the job is a replacement and not a switch. The gas appliance has to be shut off at its own valve and the pipe capped, and the Florida code says piping that is repaired or added to must be tested. Ask the building department whether the work needs a permit.
How to turn off a gas fireplace?
Use the control that lights the unit, whether that is a wall switch, a remote or the gas control knob, and follow the label on your model. One maker's instructions for a manual-pilot unit turn the control knob to OFF and wait before relighting. The glass and firebox stay hot for a while, and a gas smell after shutoff means leaving the house and calling the gas supplier.
Call a Chimney Company That Stays Local
Calling from Lakeland, Winter Haven or Auburndale? Tell us what the fireplace or chimney is doing, and we will set up a free inspection, quote the job in writing and start only after you say yes.