Chimney Cap Options, Slab vs Metal Cap
A slab sheds water off the top, and a metal cap covers the flue opening. Many chimneys need both jobs done.
- Licensed & insured
- Owned and run locally
- Family owned and run
- Same-day service available
Get Your Free Inspection
Thank you for the details
We will follow up to agree on an appointment.
Prefer the phone? Call (863) 312-5129
Short version
A masonry slab cap and a metal cap do different jobs. The slab, which trades call the crown, closes the top of the masonry and sheds water. The metal cap covers the flue opening and carries the screen that keeps animals and debris out. Florida's code requires a sloped cap with a drip edge on masonry chimneys.
Jump to
The Work, Explained
Two parts, both called a cap
The word cap covers two parts of a chimney, which is why the choice confuses people. The 2023 Florida Building Code, Residential, section R1003.9.1 says masonry chimneys shall have a concrete, metal or stone cap, a drip edge and a caulked bond break around any flue liners, and that the cap shall be sloped to shed water. In everyday use the slab across the top is the crown, and the cover over the flue opening is the chimney cap. This page compares a masonry slab with a metal cover.
Slab cap versus metal cap, side by side
The two options compare like this.
- Moisture: a sloped slab with a drip edge sheds water off the masonry, and a metal cover keeps rain out of the flue opening. The slab protects the brick, and the cover protects the flue.
- Animals: a slab alone does not close the flue outlet. A metal cap with a screen does, and the Chimney Safety Institute of America notes that animals may build nests in a flue even if the chimney is hardly used.
- Draft: a screen can restrict flow if it is too fine or too small. Section R1003.9.2 sets the net free area of a spark arrestor at no less than four times the flue outlet area.
- Upkeep: a slab can crack or crumble, and metal can rust at the fasteners or bend in wind. The Brick Industry Association says caps and copings need periodic inspection and repair.
Metal cap for chimney, including sheet metal
- Cap hood
- Spark and animal screen
- Flue tile
- Crown
- Drip edge
- Top courses of brick
A metal cap is formed from sheet metal and is fastened to the flue tile or the crown. Where a spark arrestor is installed, section R1003.9.2 requires its screen to have heat and corrosion resistance equal to 19-gage galvanized steel or 24-gage stainless steel, with openings that do not pass spheres larger than 1/2 inch nor block spheres smaller than 3/8 inch.
A sheet metal cap is sometimes built as a larger lid that covers the whole chimney top, crown included. It still has to meet the code requirements for a cap and screen.
Metal chimney cap replacement
A metal cap is replaced when it has rusted through, bent or lost its screen, or when the fasteners no longer hold. A cap that blew off should be replaced with one fastened more securely, and any damage to the crown or flue tile under it should be repaired at the same time. Our chimney cap replacement visit covers measuring, fitting and fastening the new cap.
Chimney cap size options
A cap is sized to the flue outlet it covers, and the code ties the screen's open area to that outlet. For a chimney with several flues, the cover may be one lid over the whole top or a cap per flue, which depends on the crown and is measured on site. Do not buy a cap by guesswork, since one that is too small or too tightly screened restricts draft.
Which one fits your chimney
If the crown is sound and sloped, a metal cap with a screen over the flue is usually the right addition. If the crown is cracked, flat or missing its drip edge, repair or replace it first, because a cap fastened to a failing crown loosens in wind. If the chimney is unused, the National Park Service recommends a ventilated cap so rain water does not collect.
Next step
We are a local, family-owned company in Lakeland with an experienced crew, Proudly American. Call (863) 312-5129 for a free inspection of your cap and crown and a free written estimate.
Sources
- 2023 Florida Building Code, Residential, Chapter 10, Chimneys and Fireplaces: Sections R1001.7.1, R1003.9, R1003.9.1, R1003.9.2, R1003.10, R1003.10.1, R1003.20 and R1006.1.
- Brick Industry Association Technical Note 46, Maintenance of Brick Masonry: Maintenance of caps and copings, spalling, repointing, brick replacement, vapor-permeable water repellents and estimated times to repair.
- Chimney Safety Institute of America, Homeowner Resources: Annual inspection under NFPA 211, glazed creosote, sweeping thresholds, chemical cleaners, chimney odor and air drawn down a flue.
- National Park Service Preservation Brief 39, Holding the Line, Controlling Unwanted Moisture in Historic Buildings: Moisture sources in masonry, trapped moisture under waterproof coatings, and ventilated caps on unused chimneys.
Urgent Chimney Concern?
Arrange service after immediate hazards have been addressed.
For fire, suspected gas or a carbon monoxide alarm, leave and call 911 from outside.
What a Visit From Our Lakeland Team Looks Like
-
Family owned and run
Call a family-owned business that explains the job before any work begins.
-
Owned and run locally
Locally owned and operated from our Lakeland office, with work limited to Lakeland, Winter Haven and Auburndale.
-
No hidden fees
The agreed task and price are discussed together. Added work requires another conversation.
-
Workmanship warranty
Repair workmanship is backed by a warranty. Ask what the completed job covers and how to care for it.
Questions Lakeland Homeowners Ask Us
How to seal a metal chimney cap?
A metal cap is fastened to the flue tile or crown, and the gap around the liner is closed with a caulked bond break, as the Florida Building Code requires. Sealant is not a substitute for fasteners that hold. A cap that rattles or lets water through is better replaced than caulked.
Does a chimney cap keep animals out?
A metal cap with a screen does. A slab cap on its own does not, because the flue outlet is still open. The Chimney Safety Institute of America notes that animals may nest in a flue even when the chimney is rarely used, which is one reason an unused chimney still gets a cap.
What size chimney cap do I need?
The cap is sized to the flue outlet, and where a spark arrestor is installed the code requires its net free area to be at least four times the outlet area, with openings between 3/8 and 1/2 inch. A technician measures the flue on the roof. Ordering by guess can give a cap that restricts draft.
Call a Chimney Company That Stays Local
Calling from Lakeland, Winter Haven or Auburndale? Tell us what the fireplace or chimney is doing, and we will set up a free inspection, quote the job in writing and start only after you say yes.